Sharp ARM351
- Code: U6-03
- Description: Desk No. 3 tray/LCC2 lift-up trouble
- Causes: Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor. Desk control PWB trouble Lift-up motor trouble
- Remedy: Use SIM4-2 to check the upper limit sensor detection. Use SIM4-3 to check the lift-up motor operation.