  • Code: U2-81
  • Description: Memory check sum error (Scanner)
    Scanner memory check sum error
  • Causes: EEPROM trouble EEPROM which is not initialized is installed. Control circuit freeze by noises Scanner PWB EEPROM access circuit trouble
  • Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.