  • Code: H3-10
  • Description: Main heater lamp abnormally high temperature soft detection trouble
    A/D value the fusing main heater lamp thermistor causes abnormally high temperature (over 230°C).
  • Causes: Main heater lamp thermistor defect Control PWB failure Fusing section connector contact failure
  • Remedy: Check the main heater lamp blinking with SIM 5-2-1. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14.
  • Code: H3-11
  • Description: Sub heater lamp abnormally high temperature soft detection trouble
    A/D value the fusing sub heater lamp thermistor causes abnormally high temperature (over 230°C).
  • Causes: Sub heater lamp thermistor defect Control PWB failure Fusing section connector contact failure
  • Remedy: Check the sub heater lamp blinking with SIM 5-2-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14.
  • Code: H4-00
  • Description: Main heater lamp abnormally low temperature detection
    The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power ON SW. (When the temperature of main heater lamp thermistor falls below 140°C in the standby mode or printing.) Whether temperature of main heater lamp thermistor falls below 50°C in the pre-heat mode.
  • Causes: Main heater lamp thermistor defect Main heater lamp failure Main thermostat failure Control PWB failure
  • Remedy: Check the heater lamp blinking with SIM 5- 2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check for disconnection of the heater lamp and thermostat. Check the interlock switch. Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14.
  • Code: H4-01
  • Description: Sub heater lamp abnormally low temperature detection
    The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power ON SW. (When the temperature of sub heater thermistor falls below 140°C in the standby mode or printing.) Whether temperature of sub heater lamp thermistor falls below 50°C in the pre-heat mode.
  • Causes: Sub heater lamp thermistor defect Sub heater lamp failure Sub thermostat failure Control PWB failure
  • Remedy: Check the sub heater lamp blinking with SIM 5-2-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14.
  • Code: H4-20
  • Description: Main heater lamp abnormally low temperature detection
    The setup temperature (about 25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power ON SW. (When the temperature falls below 140°C in the standby mode.)
  • Causes: Main heater thermistor defect Main heater lamp failure Main thermostat failure Control PWB failure
  • Remedy: Check the main heater lamp blinking with SIM 5-1. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14. Check that there is no foreign material in the contact section between the thermistor and the heat roller.
  • Code: H4-21
  • Description: Sub heater lamp abnormally low temperature detection
    The setup temperature (about 25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power ON SW. (When the temperature falls below 140°C in the standby mode.)
  • Causes: Sub heater thermistor defect Sub heater lamp failure Sub thermostat failure Control PWB failure
  • Remedy: Check the sub heater lamp blinking with SIM 5-2-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14. Check that there is no foreign material in the contact section between the thermistor and the heat roller.