Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
Sharp AR5012
Error Codes List page 1
|
|
- Code: E7 01
- Description: Duplex model memory setup error, memory notdetected error
- Causes: The memory is not set properly or the memory capacity is not set to the duplex setup (6M). Cancel method: Set SIM 26-39 code number to 2.
- Code: E7 02
- Description: HSYNC not detected.
- Causes: LSU (laser diode, reception element, APC circuit) trouble LSU drive circuit (ASIC) trouble
- Code: E7 10
- Description: CCD black level trouble
- Causes: CCD drive circuit (CCD PWB, ASIC, harness) trouble
- Code: E7 11
- Description: CCD white level trouble
- Causes: CCD drive circuit (CCD PWB, ASIC harness) trouble Copy lamp lighting trouble (Copy lamp, inverter PWB)
- Code: E7 12
- Description: Shading trouble (White correction)
- Causes: Dirt on white plate for scanning white level
- Code: E7 16
- Description: Laser output trouble
- Causes: LSU (laser diode, reception element, APC circuit) trouble LSU drive circuit (ASIC) trouble