  • Code: 16
  • Description: Abnormal laser output
    When the laser output is stopped, HSYNC is detected.
  • Causes: Laser abnormality MCU PWB abnormality.
  • Code: 81
  • Description: IMC communication interface error (parity)
    A parity error occurs in communication between the CPU and the IMC.
  • Causes: IMC memory defect/data abnormality
  • Code: 84
  • Description: IMC communication interface error (Framing)
    A framing error occurs in communication between the CPU and the IMC.
  • Causes: IMC memory defect/data abnormality.
  • Code: E1-00
  • Description: IMC communication trouble
    An abnormality occurs in communication between the CPU and the IMC.
  • Causes: IMC - CPU signal line abnormality IMC Memory defect/data abnormality
  • Code: E1-82
  • Description: IMC communication interface error (Overrun)
    An overrun error occurs in communication between the CPU and the IMC.
  • Causes: IMC memory defect/data abnormality.
  • Code: E7-02
  • Description: LSU trouble
    The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON)
  • Causes: LSU connector or LSU harness defect or disconnection Polygon motor rotation abnormality Laser beams are not generated. MCU PWB abnormality.