  • Code: A1-1111, A1-1113
  • Display: Motor Failure: #A1-1111. Turn off then on. Call for service if the problem persists. Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists.
  • Description: Regi/MP motor does not operate. / Regi/MP motor is operational but registers status as stopped.
  • Remedy: 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the side cover. Check if there are any foreign substances or paper around Regi./MP unit. 3) Remove the Rear-cover. 4) Check if the Regi/MP motor connector is connected correctly. 5) If the connection is OK, turn the machine on. Enter the SVC mode. Select the motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines >100-0000) a) If the motor does not operates, i) Check the signal and power with the DVM. ii) If the checked result is normal, replace the BLDC motor(JC93-00448A). iii) If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100A (220V) / JC44-00093A (110V)) - If the control signal is abnormal, replace the Main board(JC92-02452A). b) If the motor is operational, check the Pin Num 8. i) If the value is abnormal, replace the Main board(JC92-02452A). ii) If the value is normal, replace the harness.
  • Code: A1-1211, A1-1213
  • Display: Motor Failure: #A1-1211. Turn off then on. Call for service if the problem persists. Motor Failure: #A1-1213. Turn off then on. Call for service if the problem persists.
  • Description: Fuser motor does not operate. / Fuser motor is operational but regesters status as stopped.
  • Remedy: 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the side cover. Check if there are any foreign substances or paper around fuser unit. 3) Remove the rear cover. 4) Check if the fuser motor connector is connected correctly. 5) f the connection is OK, turn the machine on. Enter the SVC mode. Select the motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0120) a) If the motor does not operates, i) Check the signal and power with the DVM. ii) If the checked result is normal, replace the BLDC motor(JC93-00448A). iii) If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100A (220V) / JC44-00093A (110V)). - If the control signal is abnormal, replace the Main board(JC92-02452A). b) If the motor is operational, check the Pin Num 8. i) If the value is abnormal, replace the Main board(JC92-02452A). ii) If the value is normal, replace the harness.
  • Code: A1-2111, A1-2113
  • Display: Motor Failure: #. Turn off then on. Call for service if the problem persists.
  • Description: OPC motor does not operate. / OPC motor is operational but registers status as stopped.
  • Remedy: 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the side cover. Check if there are any foreign substances or paper around drum drive unit. 3) Remove the rear cover 4) Check if the OPC motor connector is connected correctly. 5) If the connection is OK, turn the machine on. Enter the SVC mode. Select the yellow OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0000) a) If the motor does not operates, i) Check the signal and power with the DVM. ii) If the checked result is normal, replace the BLDC motor(JC31-00123B). iii) If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100A (220V) / JC44-00093A (110V)). - if the control signal is abnormal, replace the Main board(JC92-02452A). b) If the motor is operational, check the Pin Num 8. i) If the value is abnormal, replace the Main board(JC92-02452A). ii) If the value is normal, replace the harness.
  • Code: A1-5113, A1-5512, A1-5513, A1-5610
  • Display: Motor Failure: #. Turn off then on. Call for service if the problem persists.
  • Description: Toner is not supplied normally.
  • Remedy: 1) Open the front cover. If the toner pipe is blocked, open it. 2) Turn the machine off then on. If the error persists, check the following steps. 3) Enter the SVC mode. Select the toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 111-0040) 4) If the motor does not operate, measure the motor power with DVM. - Measure 2points together. a) If 24V power is supplied, replace the Toner supply motor(JC31-00123B). b) If 24V power is not supplied, check the SMPS and main moard i) If 24V power is not generated, replace the SMPS board(JC44-00100A (220V) / JC44-00093A (110V)). ii) If the control signal is abnormal, replace the Main board(JC92-02452A).
  • Code: A2-2810, A2-2811, A2-2910, A2-2911
  • Display: Fan Failure: #. Turn off then on. Call for service if the problem persists.
  • Description: Ozone Fan or OPC In fan fan does not operate.
  • Remedy: NOTE • Ozone fan error : A2-2810 / A2-2811 • OPC In fan error : A2-2910 / A2-2911 1) Turn the machine off. 2) Remove the rear cover. 3) Check if the corresponding fan connector is connected correctly. 4) If the connection is OK, enter the SVC mode and execute fan test. (Diagnostics > Engine Dignostics > Engine Test Routines > 100-0260, 109-0040) 5) If the fan does not operate, measure the fan power. (Red line) - Measure the Red line a) If 24V power is generated, replace the defective fan. b) If 24V power is not generated, check the SMPS and main board. i) Measure 24V power on the SMPS board. If the SMPS board(JC44-00100A (220V) / JC44-00093A (110V)) is defective, replace it. ii) If the SMPS board is normal, replace the Main board(JC92-02452A). 6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. b) Check fan operation as connection or disconnection. i) If the Lock signal is 0V continually, check the harness. ii) If the harness is OK, replace the Main board(JC92-02452A). iii) If the signal value is different from the table above, replace the Fan(JC93-00500A).
  • Code: A3-3111, A3-3112, A3-3113, A3-3114
  • Display: Sensor Failure: #. Turn off then on. Call for service if the problem persists.
  • Description: The NC sensor in the fuser unit is defective. / The sensor signal is abnormal due to adefective harness.
  • Remedy: 1) Enter the SVC mode. Execute the sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics > Engine Test Routines >) - 109-0000 : Fuser Temperature A - 109-0010 : Fuser Temperature B 2) Remove and disassemble the fuser unit. 3) Measure the resistance value of the Thermistor (1404-001453). If the measured value is out of 307KOm - 430KOm at 25C, replace the thermistor. 4) If the error persists, replace the Fuser unit (JC91-01049A(220V) / JC91-01050A (110V)). 5) If the error persists after replacing fuser unit, replace the Main board(JC92-02452A).