PrintCopy.info service

Roland SP540V VersaCamm

  • Code: 0109
  • Description: Wiper Protection Error
    Even though the machine carries out the regular movement, the output of the Wiper Origin Sensor does not reach the expected value.
  • Causes: Disorder of Wiper Origin Sensor Fault of Wiper Unit Fault of Wiper Origin Sensor Cut-line or short-circuit of Cable and Flexible Cable
  • Remedy: 1) Wiper Origin Motor Replacement 2) Wiper Unit Replacement 3) Wiper Origin Sensor Replacement 4) Cable and Flexible Cable Replacement
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home