Causes: < User side > 1. Media Jam 2. Pull or Move the Carriage by hand. 3. Carriage runs into a thing/hands. 4. Media is stuck because the media end is not separated from the paper tube. 5. Heavy media is used. < Mechanical Side > 1. There is a bad contact/cut-line in the cable. 2. Screw fixing the tool carriage to wire is shifted. 3. Motor is broken./Life 4. Head/Servo Board is broken.
Remedy:
Code: 0002
Description: Sub CPU Communication Error Disorder of communication with Sub CPU
Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Sub Board.
Remedy: 1) Check Cable Connection between Main Board and Servo Board 2) Servo Board Replacement 3) Main Board Replacement
Code: 0004
Description: Feed Motor Overcurrent Error 1 (Big load is put on the motor instantaneously.)
Causes: < User side > 1. Media Jam 2. Pull or Move the Carriage by hand. 3. Carriage runs into a thing/hands. 4. Media is stuck because the media end is not separated from the paper tube. 5. Heavy media is used. < Mechanical Side > 1. There is a bad contact/cut-line in the cable. 2. Screw fixing the tool carriage to wire is shifted. 3. Motor is broken./Life 4. Head/Servo Board is broken.
Remedy:
Code: 0008
Description: Feed Motor Overcurrent Error 2 (A little load is put on the motor for a long time.)
Causes: < User side > 1. Media Jam 2. Pull or Move the Carriage by hand. 3. Carriage runs into a thing/hands. 4. Media is stuck because the media end is not separated from the paper tube. 5. Heavy media is used. < Mechanical Side > 1. There is a bad contact/cut-line in the cable. 2. Screw fixing the tool carriage to wire is shifted. 3. Motor is broken./Life 4. Head/Servo Board is broken.
Remedy:
Code: 0010
Description: Scan Motor Deviation Error
Causes: < User side > 1. Media Jam 2. Pull or Move the Carriage by hand. 3. Carriage runs into a thing/hands. 4. Media is stuck because the media end is not separated from the paper tube. 5. Heavy media is used. < Mechanical Side > 1. There is a bad contact/cut-line in the cable. 2. Screw fixing the tool carriage to wire is shifted. 3. Motor is broken./Life 4. Head/Servo Board is broken.
Remedy:
Code: 0040
Description: Scan Motor Overcurrent Error 1 (Big load is put on the motor instantaneously.)
Causes: < User side > 1. Media Jam 2. Pull or Move the Carriage by hand. 3. Carriage runs into a thing/hands. 4. Media is stuck because the media end is not separated from the paper tube. 5. Heavy media is used. < Mechanical Side > 1. There is a bad contact/cut-line in the cable. 2. Screw fixing the tool carriage to wire is shifted. 3. Motor is broken./Life 4. Head/Servo Board is broken.