PrintCopy.info service

Riso RP3700

  • Code: T98
  • Description: Hardware error
  • Causes: 005 Type-code error 029 Straight paper feed (multi-tray unit) is not set. 030 Tray 1 (multi-tray unit) is not set. 031 Tray 2 (multi-tray unit) is not set. 036 SH-PCB-to-MCTL-PCB communication error 046 The DIMM capacity does not match. 051 Touch-panel communication error 052 EEPROM read error 053 Memory settings (program, mode, user paper), failed to read the save data 054 Memory settings (program, mode, user paper), failed to write save data 055 The type code from SH-PCB does not match the type data from the MCTL PCB. 056 NVRAM check-sum error in the MCTL PCB 057 SRAM backup error in the SH-PCB 058 All SH-PCB serial-number data is zero. 063 The test-mode setting data stored was set outside the adjustment range. 064 An undefined command was sent in communication between SH-PCB and MCTL PCB. 065 Communication error 01 between SH-PCB and MCTL PCB (MCTL PCB side) 066 Communication error 02 between SH-PCB and MCTL PCB (MCTL PCB side) 067 Communication error 03 between SH-PCB and MCTL PCB (MCTL PCB side) 068 Communication error 04 between SH-PCB and MCTL PCB (MCTL PCB side) 069 Communication error 05 between SH-PCB and MCTL PCB (MCTL PCB side) 070 Communication error 06 between SH-PCB and MCTL PCB (MCTL PCB side) 071 Communication error 07 between SH-PCB and MCTL PCB (MCTL PCB side) 072 Communication error 08 between SH-PCB and MCTL PCB (MCTL PCB side) 073 Communication error 09 between SH-PCB and MCTL PCB (MCTL PCB side) 074 Communication error 10 between SH-PCB and MCTL PCB (MCTL PCB side) 075 Communication error 11 between SH-PCB and MCTL PCB (SH-PCB side) 076 Communication error 12 between SH-PCB and MCTL PCB (SH-PCB side) 077 Communication error 13 between SH-PCB and MCTL PCB (SH-PCB side) 078 Communication error 14 between SH-PCB and MCTL PCB (SH-PCB side) 079 Communication error 15 between SH-PCB and MCTL PCB (SH-PCB side) 080 Communication error 16 between SH-PCB and MCTL PCB (SH-PCB side) 081 Communication error 17 between SH-PCB and MCTL PCB (SH-PCB side) 082 Communication error 18 between SH-PCB and MCTL PCB (SH-PCB side) 083 Communication error 19 between SH-PCB and MCTL PCB (SH-PCB side) 084 Communication error 20 between SH-PCB and MCTL PCB (SH-PCB side) 085 User settings (properties, test-mode adjustment values), failed to read save data 086 User settings (properties, test-mode adjustment values), failed to write save data 087 Memory settings (program, mode, user paper), no save data set 088 User settings (properties, test-mode adjustment values), no save data set 089 Dip-SW (No.1) of SH-PCB is ON. 090 Machine code of memory settings (program, mode, user paper) does not match. 091 Check sum of memory settings (program, mode, user paper), does not match. 092 Machine code of User settings (properties, test-mode adjustment values), does not match. 093 Check sum of user settings (properties, test-mode adjustment values), does not match. 094 Communication sequence error between SH-PCB and MCTL PCB (MCTL side) 095 Check sum of user settings (properties, test-mode adjustment values), does not match during stand-by. 096 Check sum of memory settings (program, mode, user paper), does not match, during standby. 097 Test mode adjustments memorized in the drum is outside the adjustment range. 219 The TPH size code does not match the type-code data. 220 The TPH resolution code does not match the type-code data. 422 The transmitter adjustment DA setting reached the upper limit during text-mode No. 457 Auto Multi-Paper-Feed Det. Adj. 423 The transmitter adjustment DA setting reached the lower limit during text-mode No. 457 Auto Multi-Paper-Feed Det. Adj. 540 Print-drum communication: Gate-layout timeout 541 Print-drum communication: ROM-writing-complete timeout 614 Print-pressure jig: Outside the adjustment range
  • Remedy: Switch power on again
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us