PrintCopy.info service

OKI MC352

Error Codes List page 8

  • Code: 168
  • Description: Compensation thermistor error
  • Remedy: Does an error message appear? Does the error occur again? Yes Turn off and on the MFP. Turn off and on the MFP after leaving it for 30 minutes.
  • Code: 169
  • Description: An error of the Upper Side Thermistor
  • Remedy: Does the error occur again? Yes Turn on the power unit. Leave the device for 30 minutes and turn on the power unit again.
  • Code: 170, 171
  • Description: A fuser thermistor short or open circuit was detected.
  • Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the fuser unit.
  • Code: 172 ... 173
  • Description: A fuser thermistor temperature error (high or low temperature) was detected.
  • Remedy: Does the error occur again? Turn off and on the MFP. Replace the fuser unit. Replace the lowvoltage power supply, and then replace the CU/PU board when the error occurs again.
  • Code: 174
  • Description: A backup thermistor shot circuit was detected (high temperature)
  • Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the fuser unit.
  • Code: 175
  • Description: A backup thermistor open circuit was detected (low temperature)
  • Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the fuser unit.