- Code: 106
- Description: Engine control logic error
- Remedy: Does the error occur again? Yes Turn off and on the MFP Replace the CU/PU board.
- Code: 111
- Description: Duplex unit for a different model was detected.
- Remedy: Is Duplex unit for the model installed? No Install a correct Duplex unit.
- Code: 112
- Description: The 2nd tray for a model different from the MFP was detected.
- Remedy: Is the 2nd tray for the MFP installed? No Install proper 2nd tray.
- Code: 121
- Description: High-voltage power supply interface error
- Remedy: Is the cable between the CU/ PU board and the highvoltage power unit connected properly? Is a contact faulty?
Reconnect it properly. Check the highvoltage line for no poor connection. Replace the highvoltage power supply.
- Code: 122
- Description: Rear-fan error
- Remedy: Does the fan at the rear of the MFP operate? Is the connector of the fan connected properly?
Be sure of the connection of the fan. Replace the CU/PU board. Connect the fan properly. Replace the CU/PU board.
- Code: 123
- Description: Ambient humidity error or non connection of humidity sensor
- Remedy: Is the cable from the CU/PU board to the toner sensor board connected properly?
Re-connect it properly. Replace the toner sensor board.