OKI B4600
- Code: 173
- Description: Upper Heater Temp, State: Low
- Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the high voltage/sensor board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply board. • Yes Check the heater connector cord and the heater connector for poor contact .
Error Code | |
Service Mode, Troubleshooting | |
Parts Catalog | |
Compatibility | |
Downloads Files | |
Home |
Send message to us