PrintCopy.info service

Lexmark T614

  • Code: 924
  • Description: Fuser Error
    An open circuit has been detected in the Fuser Thermistor Circuit.nter is idle.
  • Remedy: 1 Fuser Lamp (Incorrect Lamp/925 Service Error) Install the correct voltage and wattage lamp or fuser assembly. 2 Fuser Lamp Remove the controller board. Run the Diagnostic Print Test and observe the lamp through the left side frame. If the lamp doesn’t come on, unplug the printer and check the continuity between the two pins on the fuser lamp cable going to the fuser assembly. If you do not measure continuity, remove the fuser assembly and check the continuity of the lamp. If incorrect, replace the lamp. If correct, replace the fuser cover assembly. 3 LVPS LVPS to Fuser Auto Docking Connector Fuser AC Cable Turn the printer off. Remove the fuser assembly. Turn the printer power on. Measure across the AC fuser cable pins for line voltage with the cable connected. If incorrect, turn the printer off and disconnect the power cord. Check the continuity of the LVPS to fuser AC cable. If incorrect, replace the cable. If correct, replace the LVPS. 4 Fuser Top Cover Assembly (Thermal Fuse/Thermistor Assembly) Disconnect the thermistor cable from the fuser board at J2. The resistance is as follows: HOT - J2-1 - J2-2 = 2.5K ohms COLD = 150K ohms to 260K ohms
Error Code
Service Mode, Troubleshooting