PrintCopy.info service

Kyocera KM2530

  • Code: C6050
  • Description: Abnormally low fixing unit thermistor temperature
    • The fixing thermistor detects temperature lower than 100 °C/212 °F for 10 s.
    • When fixing heater M is on, the temperature of the fixing thermistor is lower than 40 °C/104 °F and continues to drop for 24 s. (If the temperature in the copier is 10 °C/50 °F or less when power is turned on.)
    • When fixing heater M is on, the temperature of the fixing thermistor is lower than 40 °C/104 °F and continues to drop for 14 s. (If the temperature in the copier is higher than 10 °C/ 50 °F when power is turned on.)
  • Causes: Poor contact in the fixing unit thermistor connector terminals. Broken fixing unit thermistor wire. Fixing unit thermistor installed incorrectly. Fixing unit thermostat triggered. Fixing unit heater M or S installed incorrectly. Broken fixing unit heater M or S wire.
  • Remedy: Check the connection of connector CN10 on the main PCB and the continuity across the connector terminals. Repair or replace if necessary. Measure the resistance. If it is ∞Ω, replace the fixing unit thermistor. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit thermostat. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit heater M or S.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us