Error Codes List page 1

  • Code: 0150
  • Description: Backup memory device problem (Engine PWB)
    An error occurs in backup data read or write for the engine PWB. An error occurs in control area deletion.
  • Causes: Defective engine PWB. Data damage of EEPROM.
  • Remedy: Defective engine PWB. Replace the engine PWB and check for correct operation.
    Data damage of EEPROM. Contact the Service Administrative Division.
  • Code: 0160
  • Description: Backup memory data problem (Engine PWB)
    Data for backup data check is changed at the check after startup.
  • Causes: Defective engine PWB. Data damage of EEPROM.
  • Remedy: Defective engine PWB. Replace the engine PWB and check for correct operation.
    Data damage of EEPROM. Contact the Service Administrative Division.
  • Code: 0420
  • Description: Paper feeder communication error (optional paper feeder)
    A communication error from paper feeder is detected 10 times in succession.
  • Causes: Poor contact in the connector terminals. Defective PWB.
  • Remedy: Poor contact in the connector terminals. Check the connection of connector YC33 on the engine PWB and the connector YC1 on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary.
    Defective PWB. Replace the paper feeder main PWB or engine PWB and check for correct operation.
  • Code: 1010
  • Description: Lift motor 1 error
    When cassette 1 is inserted, lift limit switch 1 does not turn on within 12 s of lift motor 1 turning on.
  • Causes: Poor contact in the connector terminals. Broken gears or couplings of lift motor 1. Defective lift motor 1. Defective lift switch 1.
  • Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 1 and the connector YC25 on the engine PWB, and the continuity across the connector terminals. Repair or replace if necessary.
    Broken gears or couplings of lift motor 1. Replace lift motor 1.
    Defective lift motor 1. Check for continuity across the coil. If none, replace lift motor 1.
    Defective lift switch 1. Check if YC9-12 on the feed PWB goes low when lift switch 1 is turned off. If not, replace lift switch 1.
    Poor contact in the connector terminals. Check the connection of connector of lift switch 1 and the connector YC9 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary.
    Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
  • Code: 1020
  • Description: Lift motor 2 error
    When cassette 2 is inserted, lift limit switch 2 does not turn on within 12 s of lift motor 2 turning on.
  • Causes: Poor contact in the connector terminals. Broken gears or couplings of lift motor 2. Defective lift motor 2. Defective lift switch 2. Poor contact in the connector terminals. Defective PWB.
  • Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 2 and the connector YC25 on the engine PWB, and the continuity across the connector terminals. Repair or replace if necessary.
    Broken gears or couplings of lift motor 2. Replace lift motor 2.
    Defective lift motor 2. Check for continuity across the coil. If none, replace lift motor 2.
    Defective lift switch 2. Check if YC9-6 on the feed PWB goes low when lift switch 2 is turned off. If not, replace lift switch 2.
    Poor contact in the connector terminals. Check the connection of connector of lift switch 2 and the connector YC9 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary.
    Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
  • Code: 1030
  • Description: Paper feeder lift motor 1 error (optional paper feeder)
    When optional cassette 3 is inserted, paper feeder lift switch 1 does not turn on within 12 s of paper feeder lift motor 1 turning on. The lift overcurrent protective monitor signal is detected above 500 ms during driving the motor. However, the first 1 s after paper feeder lift motor 1 is turned on is excluded from detection.
  • Causes: Poor contact in the connector terminals. Broken gears or couplings of paper feeder lift motor 1. Defective paper feeder lift motor 1. Defective paper feeder lift switch 1.
  • Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary.
    Broken gears or couplings of paper feeder lift motor 1. Replace paper feeder lift motor 1.
    Defective paper feeder lift motor 1. Check for continuity across the coil. If none, replace paper feeder lift motor 1.
    Defective paper feeder lift switch 1. Check if YC1-5 on the paper feeder main PWB goes low when paper feeder lift switch 1 is turned off. If not, replace paper feeder lift switch 1.