Kyocera FS9530DN
- Code: 5300
- Description: Broken cleaning lamp wire
While the cleaning lamp is on, the broken cleaning lamp wire detection signal is detected for 2 s continuously. - Causes: Defective cleaning lamp. Defective engine PWB.
- Remedy: Defective cleaning lamp. Replace the cleaning lamp. Defective engine PWB. Replace the engine PWB and check for correct operation.