PrintCopy.info service

Konica-Minolta bizhub 160

Error Codes List page 1

  • Code: C0045
  • Description: Fuser fan motor error
    - The LOCK signal remains HIGH or LOW continuously for a predetermined period of time while the Cooling Fan Motor remains energized
  • Remedy: 1 Check the Motor connectors for connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M2 operation check 4 M3 operation check 5 Replace PWB-P.
  • Code: C0210
  • Description: H. V. abnormal
    - The Drum Charge Monitor Voltage (HVC_MON) signal falls outside a predetermined range at any time after the lapse of a predetermined period of time after the Power Switch has been turned ON.
    - The Image Transfer Voltage Monitor signal (T_MON_V) and Image Transfer Current Monitor signal (T_MON_I) fall outside a corresponding predetermined range
  • Remedy: 1 Replace Fusing Unit. 2 Replace PWB-P.
  • Code: C0500
  • Description: Fuser warm up error
    - The voltage of the Thermistor remains low for a predetermined period of time when a warm-up cycle is started.
    - The temperature detected by the Thermistor remains lower than a reference value for a predetermined period of time for the period of time that begins 5 sec. after, and ends 9 sec. after, the start of the warm-up cycle (where the temperature detected by the Thermistor is 80 °C or less).
    - The temperature detected by the Thermistor does not increase for a 3-sec. period or more for the period of time that begins after the lapse of a predetermined period of time after the Fusing Roller Heater Lamp has been turned ON and ends when the lamp is turned OFF.
    - The Fusing Roller Heater Lamp remains ON for a 30-sec. period or more (except during the period through which the Main Motor remains energized).
  • Remedy: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
  • Code: C0510
  • Description: Fuser temperature low
    - The temperature detected by the Thermistor remains lower than the set temperature continuously for a predetermined period of time while the fusing temperature control is being provided. (The set temperatures are as follows: 140 °C during a print mode at 600 dpi; 70 °C during the standby mode.)
  • Remedy: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
  • Code: C0520
  • Description: Fuser overheat
    - The temperature detected by the Thermistor remains higher than 235 °C for a predetermined period of time while the fusing temperature control is being provided.
  • Remedy: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
  • Code: C0650
  • Description: Scanner home sensor error
    - The Scanner Home Position Sensor is not detected within the predetermined period of time after the Scanner Motor has started turning.
  • Remedy: 1 M4 operation check. 2 Replace PWB-P.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us