- Description: Alignment plate motor drive malfunction
<When FS-527 is installed> • The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON. - Causes: Alignment plate motor (M13) Alignment plate home sensor (PS17) FS control board (FSCB)
- Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M13 for proper drive coupling, and correct as necessary. - - 3 PS17 I/O check, sensor check FSCB PJ17-3 (ON) FS-527 B to C-8 4 M13 operation check FSCB PJ8-1 to 4 FS-527 B to C-7 5 Change M13 - - 6 Change FSCB