Konica-Minolta bizhub C360

  • Code: C0214
  • Description: LCT shifting failure
    • The shifter stop position sensor (PS11) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop position sensor (PS11) is not blocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the shift operation began (shift to the right). • The shifter home position sensor (PS12) is not unblocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the shift operation began (shift to the right). • The shifter home position sensor (PS12) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left). • The shifter home position sensor (PS12) is not blocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the return operation began (shift to the left). • The shifter stop position sensor (PS11) is not unblocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the return operation began (shift to the left).
  • Remedy: 1 Check the connector between PS8-PCCB CN2<A> for proper connection and correct as necessary. 2 Check the connector between PS11-PCCB CN2<A> for proper connection and correct as necessary. 3 Check the connector between PS12-PCCB CN2<A>for proper connection and correct as necessary. 4 PS8 I/O check, sensor check. 5 PS11 I/O check, sensor check. 6 PS12 I/O check, sensor check. 7 Change PCCB.