PrintCopy.info service

Konica-Minolta bizhub C352

  • Code: C3851
  • Description: Abnormal low temp. (Heater)
    • The temperature of the heating roller thermistor/1 (TH1) is lower than a given level of degree for 1 second or more uninterruptedly during ready mode, low power mode or printing. • With the normal fusing temperature control, if the counting value for the zero cross signal input was not modified for the specified period of time, the counting will be performed for the zero cross signal error detection. The malfunction will be detected when the counted error value is over the specified value.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, MFPB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change MFPB. 6 Change DCPU.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?