Konica-Minolta bizhub C350
- Code: C0960
- Description: Bypass lifting motion failure
• The Bypass Lift-up Sensor is not blocked even when the Tray2 Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the standby position to the take-up position was started. • The Bypass Lift-up Sensor is not unblocked even when the Tray2 Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the take-up position to the standby position was started. - Remedy: 1 Check the M103 connector for proper connection and correct as necessary. 2 Check the connector of M103 for proper drive coupling and correct as necessary. 3 PC115 I/O check PWB-Z PJ7Z-11A (ON) 2-E 4 CL101 operation check. 5 M103 operation check PWB-Z PJ5Z-5-8 (Pulse Output) 2-V. 6 Change PWB-Z.
Error Code | |
Service Mode, Troubleshooting | |