  • Code: C3851
  • Description: Low Fuser Temperature Failure (Main)
    - The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
    - The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing.
  • Remedy: 1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.