Konica-Minolta bizhub 210
- Code: C13F0
- Description: Faulty HSYNC
Laser scanning system malfunction
- The SOS Sensor does not detect a rising edge of SOS within a given period of time after the Polygon Motor (M2) has started turning and a laser output has been started.
- The SOS Sensor detects no rising edges of SOS while VIA (image area control) is ON. - Remedy: 1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.