Konica-Minolta bizhub 164
- Code: C5102
- Description: Main motor malfunction
- The main motor (M1) lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the main motor has started turning. - Remedy: 1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 M1 operation check. 4 Change PRCB. 5 Change DCPU.
Error Code | |
Service Mode, Troubleshooting | |
Parts Catalog | |
Compatibility | |
Downloads Files | |
Home |