Description: RTC communication error
The printer causes this error and stops operation when it detects that the RTC circuit on the BOARD ASSY.,MAIN malfunctions (operates in test mode).
Causes:
Remedy: 1. Turns the printer OFF and remove the lithium battery. Leave the printer for a few seconds and then reinsert the battery and turn the printer ON. 2. Repeat Step 1 until the printer stops causing the error at power-on. 3. Start up the printer in the Serviceman mode, and set the date and time using the “RTC & USB ID & IEEE1394 ID” Basic Adjustment menu provided in the Adjustment Program.
Code: 00010027
Description: Pressure pump micro air-leak error
The printer causes the error and stops operation if the Pressure Sensor becomes “LOW” state while performing a inspection of the Pressure Motor by “1.4.6.1 Self Testing Menu (SELF TESTING)” . This error occurs only when the printer is in the SELF TESTING mode. If a micro air leak from the Pressure Motor is suspected because the motor works frequently or constantly, the SELF TESTING function allows you to check it for micro air leak before the printer causes a Service Call 00010014 for leakage of air.
Causes: • Micro air leak from the Pressure Motor. • The Pressure Tube is disconnected. • The pressure inside the pressurizing mechanism dropped within 90 seconds after finishing the last pressurizing operation.
Remedy: 1. Connect the Pressure Tube. 2. Replace the PUMP ASSY., SUPPLY .
Code: 00010028
Description: Head error
The printer causes this error and stops operation when it detects an undefined NMI in the CPU or the printhead is damaged.
Causes:
Remedy: Replace the PRINT HEAD .
Code: 0001002A
Description: CR ASIC ECU error
• Malfunction of the firmware (invalid rewriting of the register) • The Main Board is damaged.
Causes:
Remedy: 1. Installing Firmware 2. Replace the BOARD ASSY., MAIN .
Code: 0001002D
Description: The Cleaning Unit reached its end of life.
The pump counter reached the prescribed upper limit (182,000P).
Causes:
Remedy: Replace the Cleaning Unit and reset the life counter of the unit using the Adjustment Program.
Code: 00010035
Description: Pump phase detection error
Causes: A position of the pump cannot be detected after the Pump Motor rotates the prescribed number of times, or the Pump Phase Sensor is faulty. Or the fuse for the motor driver power is blown (on the Main Board).
Remedy: Check if the printer can recover from the error by turning it OFF and back ON. If the error occurs again, replace the Pump Cap Assy. or replace the Main Board Assy. .. Replace the PUMP CAP ASSY. . .. Replace the BOARD ASSY., MAIN .