PrintCopy.info service

Canon iRC3480i

Error Codes List page 1

  • Code: E001-0000
  • Description: Abnormality high temperature error of the fixing unit
    Detect high temperature by the main thermistor (software). Software detects that the temperature detected by the main thermistor is abnormally high (above 260 deg C) for 500 ms continuously.
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E001-0001
  • Description: Abnormality high temperature error of the fixing unit
    Detect high temperature by the sub thermistor (software). Software detects that the temperature detected by the sub thermistor is abnormally high (above 260 deg C) for 500 ms continuously.
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E001-0003
  • Description: Abnormality high temperature error of the fixing unit
    Detect high temperature by the sub thermistor (hardware). Hardware detects that the temperature detected by the contact type thermistor is abnormally high (above 230 deg C).
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E003-0000
  • Description: Error in the low temperature of the fixing unit
    Detects the temperature detected by the main thermistor is abnormally low (below 120 deg C) for 1 sec continuously after passing 20 sec from turning ON the fixing heater.
  • Remedy: Check the connection of the main thermistor/thermal switch. Check open circuit of heater. Replace the cover switch. Replace the fixing unit. Replace the main power supply PCB. Replace the DC controller PCB. Clear the error in service mode: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E003-0001
  • Description: Error in the low temperature of the fixing unit
    Detects the temperature detected by the sub thermistor is abnormally low (below 70 deg C) for 1 sec continuously while adjusting print temperature.
  • Remedy: Check on connection of the sub thermistor/thermo switch, Replace the fixing unit, Check on a break in the heater, Replace the cover switch, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E003-0002
  • Description: Error in the low temperature of the fixing unit
    Detects the abnormally low temperature (open circuit) when turning ON the fixing heater.
  • Remedy: Clear the error in service mode: COPIER > FUNCTION > CLEAR > ERR.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us