  • Code: E002-0000
  • Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The reading of the main thermistor is not 100 deg C 12 sec after it has exceeded 70 deg C.
  • Remedy: - Check the connector of the main/shutter thermistor for any fault in connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
  • Code: E002-0001
  • Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The reading of the main thermistor is not 150 deg C 15 sec after it has exceeded 100 deg C.
  • Remedy: - Check the connector of the main/shutter thermistor for any fault in connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
  • Code: E002-0010
  • Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The power has been turned off and then back on without resetting the error
  • Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
  • Code: E003-0000
  • Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The reading of the main thermistor is lower than 70 deg C for 2 sec or more after it has exceeded 100 deg C.
  • Remedy: connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
  • Code: E003-0010
  • Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The power has been turned off and then back on without resetting the error.
  • Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
  • Code: E004-0010
  • Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The power has been turned off and then back on without resetting the error.
  • Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)