PrintCopy.info service

Canon iR3300

  • Code: E901-0000
  • Description: The motor ready signal does not arrive within 1.3 sec after the pedestal main motor drive signal is generated
  • Causes: The connector has poor connector. The pedestal main motor is faulty. The main power supply PCB is faulty. The pedestal controller PCB is faulty. The DC controller PCB is faulty.
  • Remedy: 1. Connector Is the wiring between the pedestal controller PCB and the main power supply PCB and between the main power supply PCB and the DC controller PCB normal? NO: Correct the wiring. 2. Main power supply PCB Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply PCB about 24 V? NO: Replace the main power supply PCB. 3. Pedestal main motor Try replacing the pedestal main motor. Is the problem corrected? YES: End. 4. Pedestal controller PCB, DC controller PCB Try replacing the pedestal controller PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us