  • Description: A mounting fault of the HDD is detected when the HDD is started up from the BOOT ROM
  • Causes: The wiring is faulty (short circuit, open circuit). The HDD is faulty. The main controller PCB is faulty.
  • Remedy: 1. Wiring Are the connection and the cable between connector J1025 of the main controller PCB and the connector J2005 of the HDD normal? NO: Correct the connector/cable. 2. System software Try re-installing the system software. Is the problem corrected? YES: End. 3. HDD, Main controller PCB Try replacing the HDD, and download the system software. Is the problem corrected? YES: End. NO: Replace the main controller PCB.