Canon iR3300 Error Codes

Exploded Views and Parts List Free!

Code

E602-0001

Description

A mounting fault of the HDD is detected when the HDD is started up from the BOOT ROM

Causes

The wiring is faulty (short circuit, open circuit). The HDD is faulty. The main controller PCB is faulty.

Remedy

1. Wiring Are the connection and the cable between connector J1025 of the main controller PCB and the connector J2005 of the HDD normal? NO: Correct the connector/cable. 2. System software Try re-installing the system software. Is the problem corrected? YES: End. 3. HDD, Main controller PCB Try replacing the HDD, and download the system software. Is the problem corrected? YES: End. NO: Replace the main controller PCB.