Canon iR3300
- Code: E220-0001
- Description: A fault is detected on the inverter PCB for the scanning lamp
- Causes: The inverter PCB is faulty. The reader controller PCB is faulty.
- Remedy: 1. Wiring Is the wiring from the scanning lamp to the reader controller PCB normal? NO: Connect the connector firmly, and correct or replace the wiring. 2. Inverter PCB, Reader controller PCB Try replacing the lamp inverter PCB. Is the problem corrected? YES: End. NO: Replace the reader controller PCB.