Description: The developing assembly connector is disconnected/Disconnection of Toner sensor.
Disconnection of the wire used for detecting the connection of the toner level sensor is found. When the disconnection of the wire used for detecting the connection of the toner level sensor has been detected for 7.5 min without interruption (12.5 min in the manual /envelop cassette feeding). When the disconnection of the wire used for detecting the connection of the toner level sensor has been detected for 12.5 min without interruption.
-iR 3225
When the disconnection of the wire used for detecting the connection of the toner level sensor has been detected for 7.5 min without interruption (12.5 min in the manual /envelop cassette feeding).
-iR 3245/3235/3230
When the disconnection of the wire used for detecting the connection of the toner level sensor has been detected for 12.5 min without interruption.