  • Code: E000-0001
  • Description: The temperature of the fixing assembly is abnormally high.
    While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply. While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply. While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply. The startup control does not end 30 sec after the start of power supply.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.