  • Code: E674-0000
  • Description: A faulty occurs in the communication between the fax PCB and the main controller PCB
  • Causes: The wiring is faulty (short circuit, open circuit). The fax PCB is faulty. The main controller PCB is faulty.
  • Remedy: 1. Wiring Are the connection and the cable between the connector J 1005 on the main controller PCB and the connector J31 on the FAX PCB normal? NO: Correct the connection and the cable. 2. FAX PCB, Main controller PCB Try replacing the FAX PCB. Is the problem corrected? YES: End. NO: Replace the main controller PCB.
  • Code: E677-0001
  • Description: A fault occurs it the combination between any of the printer boards (accessories) and the main controller PCB
  • Causes: Any of the printer boards (accessories) is faulty. The main controller PCB is faulty.
  • Remedy: 1. Connector Is the printer board (accessory) connected correctly? NO: Correct the connection. 2. Printer board, Main controller PCB Try replacing the printer board. Is the problem corrected? YES: End. NO: Replace the main controller PCB.
  • Code: E710-0001
  • Description: When the main power is turned on, the communication IC (IPC) on the reader controller PCB cannot be initialized
  • Causes: The DC controller PCB is faulty. The reader controller PCB is faulty. The machine controller PCB is faulty.
  • Remedy: Turn off and then on the main power switch. Is the problem corrected? YES: End. NO: If E7100001, replace the reader controller PCB. If E710-002, replace the DC controller PCB. If E71-0003, replace the main controller PCB.
  • Code: E710-0002
  • Description: When the main power is turned on, the communication IC (IPC) on the DC controller PCB cannot be initialized
  • Causes: The DC controller PCB is faulty. The reader controller PCB is faulty. The machine controller PCB is faulty.
  • Remedy: Turn off and then on the main power switch. Is the problem corrected? YES: End. NO: If E7100001, replace the reader controller PCB. If E710-002, replace the DC controller PCB. If E71-0003, replace the main controller PCB.
  • Code: E710-0003
  • Description: When the main power is trend on, the communication IC (IPC) on the main controller PCB cannot be initialized
  • Causes: The DC controller PCB is faulty. The reader controller PCB is faulty. The machine controller PCB is faulty.
  • Remedy: Turn off and then on the main power switch. Is the problem corrected? YES: End. NO: If E7100001, replace the reader controller PCB. If E710-002, replace the DC controller PCB. If E71-0003, replace the main controller PCB.
  • Code: E711-0001
  • Description: Data is written to the error register of the communication IC (IPC) on the reader controller PCB four times or more within 1.5 sec
  • Causes: The connector has poor connection. The ADF controller PCB is faulty. The finisher controller PCB is faulty. The DA unit PCB is faulty. The card reader PCB is faulty.
  • Remedy: Connector, ADF controller PCB Is the interface cable between the ADF controller PCB an the reader controller PCB normal? NO: Correct the cable. YES: Replace the ADF controller PCB.