Description: The temperature of the fixing assembly is abnormally high.
When the main power switch is turned on, the reading of the main thermistor does not reach 70 deg C within 3 min 30 sec.
Remedy: - Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Code: E000-0010
Description: The temperature of the fixing assembly is abnormally high.
The power is turned off and then on without clearing the error.
Remedy: - Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Code: E001-0001
Description: The over-rising in temperature of the fixing assembly is detected.
The hardware port detects a fault.
Remedy: - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Code: E001-0002
Description: The over-rising in temperature of the fixing assembly is detected.
Either the main thermistor or the sub thermistor detects 230 deg C or higher for 2 sec.
Remedy: - Check if the main thermistor and the sub thermistor are mounted properly. - Replace the main thermistor or the sub thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Code: E001-0003
Description: The over-rising in temperature of the fixing assembly is detected.
The reading of the main thermistor is higher than that of the sub thermistor by 50 deg C or more for 1 sec.
Remedy: Check if the main thermistor and the sub thermistor are mounted properly. - Replace the main thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Code: E001-0004
Description: The over-rising in temperature of the fixing assembly is detected.
The reading of the main thermistor is lower than that of the sub thermistor by 50 deg C or more for 1 sec.
Remedy: - Check if the main thermistor is mounted properly. - Replace the main thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).