  • Code: 0B00
  • Description: There was no response from the panel for the specified time for any reason.
  • Causes: 1 Panel PCB failure. 2 Touch panel PCB failure. 3 Main PCB failure
  • Remedy: 1 Panel PCB failure Replace the panel PCB ASSY. 2 Touch panel PCB failure Replace the touch panel PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: 0C01, 0C02, 0C03, 0C04
  • Description: Log registration failed.
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 0E00
  • Description: Communication between the panel PCB and the main PCB cannot be established at machine startup.
  • Causes: 1 Connection failure of the panel PCB harness. 2 Panel PCB failure. 3 Touch panel PCB failure. 4 Main PCB failure.
  • Remedy: 1 Connection failure of the panel PCB harness Reconnect the panel PCB harness. 2 Panel PCB failure Replace the panel PCB ASSY. 3 Touch panel PCB failure Replace the touch panel PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 0F00
  • Description: The back cover sensor detected that the cover was open in duplex printing mode.
  • Causes: 1 Connection failure of the back cover sensor harness. 2 Back cover sensor attachment failure. 3 Broken rib (on the right inside the back cover) where the back cover switch is pressed. 4 Damaged duplex tray. 5 Back cover sensor failure. 6 Main PCB failure
  • Remedy: 1 Connection failure of the back cover sensor harness Check the connection of the back cover sensor harness, and reconnect it if necessary. 2 Back cover sensor attachment failure Reattach the back cover sensor. 3 Broken rib (on the right inside the back cover) where the back cover switch is pressed Replace the back cover. 4 Damaged duplex tray Replace the duplex tray. 5 Back cover sensor failure Replace the back cover switch harness ASSY. 6 Main PCB failure Replace the main PCB ASSY.
  • Code: 3600
  • Description: An error occurred in the high-voltage power supply PCB.
  • Causes: 1 High-voltage power supply PCB failure. 2 Main PCB failure
  • Remedy: 1 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.
  • Code: 3B00
  • Description: An error occurred during access to the DRAM in the main PCB.
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.