  • Code: 50
  • Description: Replacement time of the drum unit
  • Causes: • Replace the drum unit with a new one.
  • Remedy: 1 Main PCB failure Replace the main PCB ASSY.
  • Code: 56
  • Description: Fuser cover opened
  • Causes: • Check if the Fuser cover is closed correctly. Harness connection failure of back cover switch ASSY Eject actuator failure Eject sensor PCB ASSY failure Main PCB failure
  • Remedy: 1 Harness connection failure of back cover switch ASSY Check the harness connection of the back cover switch ASSY and reconnect it. 2 Eject actuator failure Re-assemble the eject actuator 3 Eject sensor PCB ASSY failure Replace the eject sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 58
  • Description: Fuser unit failure (Stand ready in the given time)
  • Causes:
  • Remedy: 1 Harness connection failure between fuser unit and eject sensor PCB Check the harness connection between the fuser unit and eject sensor PCB, and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB failure Replace the LVPS PCB unit. 4 Eject sensor PCB ASSY failure Replace the eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
  • Code: 59
  • Description: Fuser unit failure
  • Causes:
  • Remedy: 1 Harness connection failure between fuser unit and eject sensor PCB Check the harness connection between the fuser unit and eject sensor PCB, and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB failure Replace the LVPS PCB unit. 4 Eject sensor PCB ASSY failure Replace the eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
  • Code: 5A
  • Description: HVPS PCB ASSY failure
  • Causes: HVPS PCB failure (Developing bias voltage failure) HVPS PCB ASSY harness connection failure HVPS PCB failure Main PCB failure
  • Remedy: 1 HVPS PCB ASSY harness connection failure Check the harness connection between the HVPS PCB and main PCB. Then, reconnect them. 2 HVPS PCB failure Replace the HVPS PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: 5B
  • Description: New toner detecting lever malfunction
  • Causes: New toner detection switch harness connection failure New toner detection switch failure Main PCB failure
  • Remedy: 1 New toner detection switch harness connection failure Check the harness connection of the new toner detection switch. Then, reconnect it. 2 New toner detection switch failure Replace the new toner harness ASSY. 3 Main PCB failure Replace the main PCB ASSY.